Adhesion from supplemental bentonite placed at GCL overlaps
Richard W.I. Brachman, Simon Gudina, R. Kerry Rowe , W. Andy Take
In the proceedings of: GEO2010 Calgary: 63rd Canadian Geotechnical Conference & 6th Canadian Permafrost ConferenceSession: T1-C
ABSTRACT: Results are presented from a new index test conducted to measure the in-plane shearing resistance of four different overlapped GCL seams with supplemental bentonite after being exposed to one wetting and drying cycle. All GCLs required tensile force to overcome the adhesion that developed between the supplemental bentonite and the upper and lower geotextiles of the GCLs and separate the overlap. While three of the GCLs tested showed similar results, the lowest adhesion was measured for an overlap that involved a slit-film woven geotextile where the needle-punched fibres from the GCL were thermally melted to the woven geotextile which produced an interface that was less effective in bonding with the supplemental bentonite.
RÉSUMÉ: Les résultats sont présentés dans un nouveau test index effectué pour mesurer la résistance tondre en plan de quatre différent coutures des géosynthétique bentonitique (GSB) avec la bentonite supplémentaire après un cycle de mouillage et un cycle de séchage. Tous les GSB a nécessités la force de traction pour surmonter l'interaction physique qui a développé entre la bentonite supplémentaire et les géotextiles supérieure et inférieure des GSB et de séparer le chevauchement. En moyenne, la plus grande force a été mesurée pour le chevauchement des non-tissés géotextiles aiguille-perforés qui n'ont pas été traités thermiquement alors que la supplémentaire bentonite qui on été hydratée et plus tard séchées était plus capable d'ancrer entre les fibres discontinues des géotextiles. L'adhérence plus bas a été mesurée pour un chevauchement qui cause une fente film géotextile tissé lors que les fibres aiguille-perforés de GSB ont fondu thermiquement aux tissus géotextiles qui a produit une interface qui était moins efficace en liaison avec la bentonite supplémentaire.
Please include this code when submitting a data update: GEO2010_98
Access this article:
Canadian Geotechnical Society members can access to this article, along with all other Canadian Geotechnical Conference proceedings, in the Member Area. Conference proceedings are also available in many libraries.
Cite this article:
Richard W.I. Brachman; Simon Gudina; R. Kerry Rowe; W. Andy Take (2010) Adhesion from supplemental bentonite placed at GCL overlaps in GEO2010. Ottawa, Ontario: Canadian Geotechnical Society.
@article{GEO2010_180,
author = Richard W.I. Brachman; Simon Gudina; R. Kerry Rowe; W. Andy Take,
title = Adhesion from supplemental bentonite placed at GCL overlaps ,
year = 2010
}
title = Adhesion from supplemental bentonite placed at GCL overlaps ,
year = 2010
}